Factory direct supply pulse valve MK-50, MK-62, MK-76, VP-20, VP-25, VP-40

$8.79

  • Brand: Parker
  • Product Code: MK-50
  • Availability: In Stock

- +
Pulse valve is the execution mechanism and key component of pulse jet cleaning device. It is mainly divided into three types: right-angle type, submerged type and straight-through type. It is worth noting that the working pressure of domestic pulse valve; right-angle valve and straight-through valve are 0.4- 0.6MPa; no matter which type of valve is imported, the working pressure range is 0.4-0.6MPa. There is no difference between the pressure and the application pressure of the two types of valves.
 
1) Structure and working principle of right-angle pulse valve. The characteristic of the right-angle pulse valve is that the air inlet and outlet pipes of the valve are at a right angle of 90 degrees. The diaphragm in the valve divides the pulse valve into two air chambers, the front and the rear. When the compressed air is connected, the compressed air enters the rear air chamber through the orifice. At this time, the pressure of the air chamber will make the diaphragm close to the output port of the valve. The pulse valve is closed. The electric signal of the pulse controller makes the armature of the electromagnetic pulse valve move, the vent hole of the air chamber behind the valve is opened, the vocal cord of the rear air chamber loses pressure, the diaphragm moves back, the compressed air can be sprayed through the valve output port, and the pulse valve is in the open state. Compressed air is instantly ejected from the valve to form a jet airflow. The technical parameters of TMF-Z (DMF-Z) right-angle electromagnetic pulse valve are as follows: Adapt to the environment: temperature -1055 ℃; relative humidity not greater than 85%.
 
Working medium: clean air, dew point -20℃. Blowing air source pressure: 0.3-0.6MPa. Working voltage and current of electromagnetic pilot valve: DC24V, 0.8A; AC220V, 0.14A; AC110V, 0.3A The air inlet of the pulse valve is connected to the air bag, and the air outlet is connected to the blowing pipe. When connecting, tetrafluoroethylene raw material tape should be used between the threads to ensure sealing. When connecting, it should be noted that the length of the incoming thread at the intake end should not be greater than one-third of the thread connecting wire.
 
2) Construction principle of submerged pulse valve. The submerged pulse valve adopts the installation method of being submerged in the air bag, so it is called submerged type. Compared with other structural forms, it reduces the resistance of the flow passage and the pressure of the blowing air source, so it can be suitable for low pressure occasions, and can reduce energy consumption and prolong the life of the diaphragm.
 
The technical parameters of the submerged electromagnetic pulse valve and the right-angle pulse valve are different: the pressure of the injection gas source: 0.2-0.3MPa, or 0.3-0.6MPa3) straight-through pulse valve. The structural feature of the straight-through pulse valve is that the center line of the air inlet and outlet is on a straight line, so it is called a straight-through valve. The pulse valve diaphragm divides the pulse valve into two air chambers, the front and the rear. When the compressed air is connected, the pulse valve is in a closed state. , the opening action principle is the same as that of the right-angle valve, but the flow direction of the air jet is different. The advantage of the straight-through pulse valve is that it is easy to install, and it is often used in the air box pulse dust collector; the disadvantage is that the airflow through the valve body has a large resistance. The straight-through electromagnetic pulse valve has the same technical parameters as the right-angle pulse valve.
 
The electromagnetic pulse valve of the ash cleaning unit of the pulse dust collector should strictly abide by the environmental requirements when using it. Can the electromagnetic pulse valve run normally and smoothly under the environmental conditions of the electromagnetic pulse valve:
 
1. According to the type of power supply, select AC and DC solenoid valves respectively. Generally speaking, AC power is easy to use.
 
2. In the environment with high relative humidity and water droplets and rain, the waterproof solenoid valve should be selected.
 
3. For use in corrosive or explosive environments, corrosion-resistant solenoid valves should be selected first according to safety requirements.
 
4. Power conditions of electromagnetic pulse valve.
 
5. The power supply voltage fluctuation is usually +%10%.-15% for AC, and ±%10 for DC is allowed. If it is out of tolerance, you must take voltage stabilization measures or put forward special order requirements.
 
6. There are often vibrations, bumps and shocks in the environment, and special varieties should be selected, such as marine solenoid valves.
 
7. The maximum and minimum temperature of the environment should be selected within the allowable range. If there is any excess, a special order should be made.
 
8. The rated current and power consumption should be selected according to the power supply capacity. It should be noted that the VA value is relatively high during AC starting, and the indirect conduction electromagnetic pulse valve should be preferred when the capacity is insufficient.
 
9. If the environmental space is limited, please use the multi-function solenoid valve, because it saves the bypass and three manual valves and is convenient for online maintenance
 
Angle pulse valve, the full name of 'right-angle electromagnetic pulse valve', is characterized in that the angle between its inlet and outlet is 90 degrees. It is suitable for the installation and connection of the air storage tank and the dust removal blowing pipe. The air flow is smooth and can provide pulses that meet the requirements. Dust-cleaning airflow.
 
The structure and working principle of right-angle pulse valve.
 
The characteristic of the right-angle pulse valve is that the air inlet and outlet pipes of the valve are at a right angle of 90 degrees. The diaphragm in the valve divides the pulse valve into two air chambers, the front and the rear. When the compressed air is connected, the compressed air enters the rear air chamber through the orifice. At this time, the pressure of the rear air chamber will make the diaphragm close to the output port of the valve. , the pulse valve is in the "closed" state.
 
The electric signal of the pulse blowing controller makes the armature of the electromagnetic pulse valve move, the vent hole of the air chamber behind the valve is opened, the rear air chamber loses pressure rapidly, the diaphragm moves backward, the compressed air can be sprayed through the valve output port, and the pulse valve is in the "open" state. "state. Compressed air is instantly ejected from the valve to form a jet airflow.
 
When the electrical signal of the pulse controller disappears, the armature of the pulse valve is reset, the vent hole of the rear air chamber is closed, and the pressure of the rear air chamber rises to make the diaphragm close to the valve outlet, and the pulse valve is in the "closed" state again.
 
Appearance Plan of Right Angle Pulse Valve
 
  Right-angle pulse valve outline plan technical parameters of right-angle pulse valve:
 
Adapt to the environment: temperature -10-55 degrees Celsius; relative humidity not greater than 85%
 
Working medium: clean air, dew point -20 degrees Celsius.
 
Blowing pressure: 0.3-0.8MPa.
 
Solenoid pilot valve operating voltage: DC24V, AC220V, AC110V.
 
AMF-Z-25, AMF-Z-40, AMF-Z-62 Fleet Electromagnetic Pulse Valve
AMF-Z-50, AMF-Z-40S, AMF-Z-50S pulse valve manufacturer
AMF-Z-62S, AMF-Z-76S, AMF-20A Fulid electromagnetic pulse valve
AMF-20, AMF-25, AMF-40, AMF-62 electromagnetic pulse valve
AMF-20J, AMF-25J, AMF-20B, AMF-62S pulse valve manufacturer
AMF-25B, AMF-65, AMF-76, AMF-40S Freed Electromagnetic Pulse Valve
AMF-Z-20A, AMF-Z-25J, AMF-Z-20J pulse valve manufacturer
AMF-Z-25, AMF-Z-20, AMF-65, AYMF-50S electromagnetic pulse valve
DYM-89,DMF-Y-76S,DMF-Y-62S,AYMF-76 electromagnetic pulse valve price
DMF-Y-50S,DMF-Y-40S,DMF-Y-25S Freed Electromagnetic Pulse Valve
DMF-Y-102S, DMY-II-80, AMF-Y-76S pulse valve manufacturer
AMF-Y-76, SP-50, SP-75, SQP-75, AYMF-76S electromagnetic pulse valve
UM-40,UM-50,UM-65,UM-20,UM-25 pulse valve manufacturer
UM-76, CA50TX/3451, CA50T010-300 Fulid electromagnetic pulse valve
CA50TX/3452, CA50T010-301, CA50TX/3453 electromagnetic pulse valve
CA50T010-305, CA62TX/3454, CA62TX/3455 pulse valve manufacturer
CA62TX/3456, CA20T010-300, CA25T010-300 electromagnetic pulse valve
CA32T010-300, CA35T010-300, CA40T010-300 electromagnetic pulse valve price
CA45T010-300, CA50T010-300, CA62T010-300 Fuli De electromagnetic pulse valve
CA76T010-300,DMF-45DD,DMF-A-20,DMF-A-25 pulse valve manufacturer
DMF-A-62S,DMF-A-Y-76S,DMF-D-20,DMF-A-50S electromagnetic pulse valve
DMF-D-25,DMF-D-40S,DMF-D-50S,DMF-A-40S Freed Electromagnetic Pulse Valve
DMF-D-62S, DMF-D-76S, DMF-DY-50S, DMF-DY-62S electromagnetic pulse valve
DMF-Y-40S,DMF-Z-40SS,DMF-Y-62S,DMF-Y-25 pulse valve manufacturer
DMF-Z-50S,DMF-Z-62S,MCF-Z-20P electromagnetic pulse valve
MCF-Z-50S,MCF-Z-50S,MCF-Z-62S Fulid electromagnetic pulse valve
MCF-Z-76S, DMF-Z-20A, DCF-Z-20 right angle pulse valve
DCF-Z-25, DCF-Z-40, DCF-Z-50 Fleet Electromagnetic Pulse Valve
DCF-Z-62, DCF-Z-40S, DCF-Z-50S electromagnetic pulse valve
DCF-Z-62S, DCF-Z-76S, AMF-Z-25 right angle pulse valve
AMF-Z-40, AMF-Z-62, AMF-Z-50 electromagnetic pulse valve
AMF-Z-40S, AMF-Z-50S, AMF-Z-62S right angle pulse valve
AMF-Z-76S, AMF-20A, AMF-20 electromagnetic pulse valve
AMF-25, AMF-40, AMF-62 Fulid electromagnetic pulse valve
AMF-40S, AMF-62S, AMF-20J right angle pulse valve
AMF-25J, AMF-20B, AMF-25B electromagnetic pulse valve
AMF-65, AMF-76, AMF-Z-20A Fulid electromagnetic pulse valve
AMF-Z-25J, AMF-Z-20J, AMF-Z-25 right angle pulse valve
AMF-Z-20, AMF-65, right angle pulse valve
 

Write a review

Note: HTML is not translated!
Bad Good

Tags: MK-50